Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 104
Filter
1.
Braz. oral res. (Online) ; 38: e006, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1528151

ABSTRACT

Abstract The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.

2.
Braz. dent. j ; 35: e24, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550089

ABSTRACT

Abstract: The aim was to evaluate primary implant stability and bone microarchitecture in two drilling situations, by comparing the conventional technique (CT) and osseodensification (OD) (Versah Burs - Jackson - Mississippi - USA). The implant insertion torque (IT), implant stability quotient (ISQ), and the peri-implant trabecular microstructure were assessed on bone fragments obtained from pig's tibia (n=12), divided between CT (n=6) and OD (n=6). After the drilling procedure, the implants were installed (3.5x8.5 mm, Epikut - SIN - São Paulo - Brazil). The IT and ISQ were measured using a digital torque wrench and resonance frequency analysis. Then, the bone fragments containing the implants were removed with a trephine and analyzed by Microtomography (µCT, 8.0 µm). The comparison between groups was performed using the unpaired t-test (α=0.05). The results revealed that OD promotes a higher insertion torque (CT: 7.67±2.44 Ncm; OD: 19.78±5.26 Ncm) (p=0.0005), although ISQ was not different (CT: 61.33±4.66; OD: 63.25±4.58) (p=0.48). There was a significant increase in peri-implant bone volume (CT: 23.17±3.39 mm3; OD: 32.01±5.75 mm3) (p=0.008), and trabecular parameters: separation (CT: 0.4357±0.03 mm; OD: 0.3865±0.04 mm) (p=0.0449), number (CT: 1.626±0.18 1/mm; OD: 1.946±0.13 1/mm) (p=0.007), and thickness (CT: 0.1130±0.009 mm; OD: 0.1328±0.015 mm) (p=0.02). Structure model index (SMI) data demonstrate no significant differences between groups (CT: 1.7±0.2; OD: 1.4±0.4) (p=0.12). In conclusion, OD increases the insertion torque values and promotes beneficial changes regarding bone microarchitecture compared with CT, revealing more peri-implant bone volume with consequent higher primary stability.


Resumo O objetivo deste estudo foi avaliar a estabilidade de implante e a microarquitetura óssea em duas técnicas de fresagem, comparando a técnica convencional (CT) e a osseodensificação (OD) (Versah Burs - Jackson - Mississippi - EUA). O torque de inserção do implante (IT), quociente de estabilidade primária (ISQ) e a estrutura trabecular peri-implantar foram avaliados em fragmentos ósseos obtidos de tíbia de porco (n=12), divididos entre CT (n=6) e OD (n=6). Após o procedimento de fresagem, foram instalados implantes (3,5x8,5 mm, Epikut - SIN - São Paulo - Brasil). O IT e o ISQ foram aferidos por meio de um torquimetro digital e análise de frequência de ressonância. Em seguida, os fragmentos ósseos contendo os implantes foram removidos com trefina e analisados ​​por microtomografia computadorizada (µCT, 8,0 µm). A comparação entre os grupos foi realizada por meio do teste-t não-pareado (α=0.05). Os resultados revelaram que a OD promove maior torque de inserção (CT: 7,67 ± 2,44º Ncm; OD: 19,78 ± 5,26 Ncm) (p=0,0005), embora a estabilidade primária não tenha sido diferente (CT: 61.33 ± 4.66; OD:63.25 ± 4.58) (p=0,48). Houve um aumento significativo no volume ósseo peri-implantar (CT: 23,17±3,39 mm3; OD: 32,01±5,75 mm3) (p=0,0089) e parâmetros trabeculares: separação (CT: 0,4357 ± 0,03 mm; OD: 0,3865 ± 0,04 mm) (p=0,0449), número (CT: 1,626 ± 0,18 1/mm; OD: 1,946 ± 0,13 1/mm) (p=0,007) e espessura (CT: 0,1130 ± 0,009 mm; OD: 0,1328 ± 0,015 mm) (p=0,02) O índice de modelo estrutural (SMI) não demostrou diferença estatisticamente significativa (p=0.1228). Concluindo, OD apresenta maiores valores de torque de inserção e promove mudanças benéficas na microarquitetura óssea em comparação com a TC, revelando maior volume ósseo peri-implantar.

3.
Odovtos (En línea) ; 25(3): 32-42, Sep.-Dec. 2023. tab, graf
Article in English | LILACS, BBO, SaludCR | ID: biblio-1529067

ABSTRACT

Abstract The aim of this study was to compare the filling capacity in curved root canal using a new continuous wave of condensation technique (Termo Pack II, Easy Dental Equipments, Brazil) or lateral compaction. The percentage of voids in the filling of mesial root canals of mandibular molars was assessed by micro-computed tomography (micro-CT). Mesial root canals (n=24) of mandibular molars with a degree of curvature between 20° and 40° were prepared using rotary system (ProDesign Logic, Easy, Brazil) up to #35, .05 taper. The root canals were filled by using the continuous wave of condensation system or lateral compaction and AH Plus sealer (n=12). Scanning at 9 µm was performed after preparation and after filling by using micro-CT SkyScan 1176. The volumetric percentage of filling material and voids (total length and in each root canal third) were calculated. Data were analyzed using ANOVA/ Tukey and Student's t tests (α=0.05). Before the filling techniques, the root canals volume after preparation was similar (p>0.05). The root canals filled by the continuous wave of condensation technique presented the lowest percentage of voids, and the greatest percentage of filling material in total length and thirds (cervical, middle and apical) (p<0.05). Both techniques were not able of completely filling the root canals. The continuous wave of condensation technique Termo Pack II promoted better root canal filling in curved root canals, when compared with lateral compaction.


Resumen El objetivo de este estudio fue comparar la capacidad de obturación en conductos radiculares curvos utilizando una nueva técnica de condensación de onda continua (Termo Pack II, Easy Dental Equipments, Brasil) vs compactación lateral. El porcentaje de brechas en la obturación de los conductos radiculares mesiales de los molares mandibulares se evaluó mediante microtomografía computarizada (micro-CT). Se prepararon conductos radiculares mesiales (n=24) de molares mandibulares con un grado de curvatura entre 20° y 40° utilizando un sistema rotatorio (ProDesign Logic, Easy, Brasil) al #35, conicidad 0,05. Los conductos radiculares se obturaron utilizando un sistema de condensación de onda contínua o compactación lateral y cemento AH Plus (n=12). Se realizó un escaneo de 9 µm después de la preparación y después de la obturación usando el micro-CT SkyScan 1176. Se calculó el porcentaje volumétrico de material de obturación y vacíos (longitud total y en cada tercio del conducto radicular). Los datos se analizaron utilizando las pruebas ANOVA/Tukey y t de Student (α=0,05). Antes de las técnicas de obturación, el volumen de los conductos radiculares después de la preparación fue similar (p>0,05). Los conductos radiculares obturados con la técnica de condensación por onda contínua presentaron el menor porcentaje de vacíos y el mayor porcentaje de material de obturación en longitud total y en tercios (cervical, medio y apical) (p<0,05). Ambas técnicas no fueron capaces de llenar completamente los conductos radiculares. La técnica de condensación de onda contínua Termo Pack II promovió un mejor relleno del conducto radicular en conductos radiculares curvos en comparación con la compactación lateral.


Subject(s)
Root Canal Obturation/instrumentation , Condensation , Dental Pulp , X-Ray Microtomography/instrumentation
4.
Acta odontol. latinoam ; 36(3): 163-168, Dec. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533522

ABSTRACT

ABSTRACT Root canal morphology and its anatomical variations pose a great challenge to endodontists Aim The aim of this in silico study was to perform a qualitative and quantitative analysis of the threedimensional morphological characteristics of the isthmus in the mesial root canals of mandibular molars using microcomputed tomography (micro-CT) Material and Method Six hundred first mandibular molars were selected, including 317 with two mesial canals with isthmuses between the canals, and fully formed root. Isthmus morphology was determined in 3D longitudinal sections using Fan et al. (2010) classification. Root length, and the volume and area of apical and coronal level were measured. Additionally, the structural model index (SMI) of the canals were also assessed Results The prevalence of isthmuses in the mesial root canals was 32% type II, 29% type III, 22% type IV, and 17% type I. The root length was found to be 9.1±0.5 mm, the volume and area, of all root canal system, were 41.8±40.1 mm3 and 63.6±24.2 mm2 respectively. The isthmi volume and area alone were 11.06±9.03 mm3 and 30.02±11.02 mm2. The study confirmed that isthmuses are present in mesial canals of mandibular first molars, being more frequent in the apical third Conclusion The high prevalence of isthmuses with complex morphological features underscores the importance of using intracanal medications to disinfect areas unprepared by instruments.


RESUMO A morfologia do canal radicular e suas variações anatômicas representam um grande desafio para os endodontistas. O objetivo deste estudo ex vivo foi realizar uma análise qualitativa e quantitativa das características morfológicas tridimensionais do istmo nos canais mesiais de molares inferiores por meio de microtomografia computadorizada (micro-CT) Material e Método Foram selecionados 600 primeiros molares inferiores, incluindo 317 com dois canais mesiais com istmos e raiz totalmente formada. A morfologia do istmo foi determinada em cortes longitudinais 3D usando a classificação Fan et al. (2010). Foram mensurados o comprimento da raiz, o volume e a área apical e coronal e da cavidade pulpar. Adicionalmente, também foram avaliados o structure model index (SMI) dos canais Resultados A prevalência de istmos nos canais mesiais foi de 32% tipo II, 29% tipo III, 22% tipo IV e 17% tipo I. O comprimento da raiz foi de 9,1±0,5 mm, o volume e a área de todo o sistema de canais radiculares foram de 41.8±40.1 mm3 e 63.6±24.2 mm2, respectivamente. O volume e área do istmo isoladamente foram 11.06±9,03 mm3 e 30.02±11.02 mm2. O estudo confirmou que os istmos estão presentes em canais mesiais dos primeiros molares inferiores, sendo mais frequentes no terço apical Conclusão A alta prevalência de istmos com características morfológicas complexas ressalta a importância do uso de medicação intracanal para desinfecção de áreas não tocadas por instrumentos.

5.
Acta odontol. latinoam ; 36(3): 177-182, Dec. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533524

ABSTRACT

ABSTRACT Current instrumentation systems cannot fully prepare oval root canal systems. This may cause accumulation of hard tissue debris and fail to eliminate bacteria from areas inaccessible to instrumentation, which could perpetuate periapical inflammation and jeopardize the success of endodontic treatment Aim To evaluate the performance of two endodontic systems in oval canals by investigating the changes in volume, unprepared areas, and centering ability of XP-endo Shaper (XPS) and WaveOne Gold (WOG) in oval canals using microcomputed tomography (micro-CT) Materials and Method Thirty mandibular canines were scanned before and after preparation with WOG (25/.07 and 35/.06) or XPS (30/.01) to evaluate the volume, surface area, and canal centralization at 4 mm and 10 mm from the apical foramen Results Volume and surface area increased significantly after preparation with both systems (p<0.05). However, no significant difference was observed in the unprepared areas, regarding either the entire canal (26.21% for WOG and 30.10% for XPS), or the apical segment (18.82% for WOG and 14.63% for XPS) (p >0.05) Conclusions Both systems maintained canal centralization, with no difference between them. XPS and WOG had similar shaping abilities in the mandibular canine, but left almost one third of the unprepared areas.


RESUMO Os sistemas de instrumentação atuais são incapazes de preparar completamente os sistemas de canais radiculares do canal oval, o que pode levar ao acúmulo de detritos de tecido duro e manter micro-organismos em áreas inacessíveis à instrumentação. Essas bactérias poderiam perpetuar a inflamação periapical e comprometer o sucesso do tratamento endodôntico Objetivo Para avaliar o comportamento de dois sistemas endodônticos em canais ovais, esse estudo investigou as alterações no volume, áreas não preparadas e capacidade de centralização do XP-endo Shaper (XPS) e do WaveOne Gold (WOG) em canais ovais usando microtomografia computadorizada (micro-CT) Material e métodos Trinta caninos inferiores foram escaneados antes e depois do preparo com WOG (25/.07 e 35/.06) ou XPS (30/.01) para avaliar o volume, a área de superfície e a centralização do canal a 4 mm e 10 mm do forame apical Resultados O volume e a área de superfície aumentaram significativamente após o preparo com ambos os sistemas (p<0,05). No entanto, não foram observadas diferenças significativas nas áreas não preparadas, não apenas em todo o canal (26,21% para WOG e 30,10% para XPS), mas também no segmento apical (18,82% para WOG e 14,63% para XPS) (p >0,05) Conclusão Ambos os sistemas mantiveram a centralização do canal, sem diferenças entre eles. O XPS e o WOG tiveram habilidades de modelagem semelhantes no canino mandibular, mas deixaram quase um terço das áreas do canal sem preparo.

6.
Braz. dent. j ; 34(5): 29-35, Sept.-Oct. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1528019

ABSTRACT

Abstract This study aimed to evaluate the effect of apicoectomy performed with a bur or an ultrasonic tip on the adaptation of the filling material to root canal dentin. Twenty human mandibular incisors were selected and prepared with a ProDesign Logic system up to diameter 40/.05. The root canals were filled with Bio-C Sealer (Angelus, PR, Brazil) using the single cone technique and were stored at 37ºC and 95% relative humidity for 7 days. After this period, the apicoectomy of the 3 millimeters of the root apex was performed using Endo-Z bur (Dentsply Sirona) or Bladesonic ultrasonic tip (Helse Ultrasonic, Santa Rosa de Viterbo, Brazil) (n=10). The specimens were scanned by micro-computed tomography (micro-CT; SkyScan 1176) with a voxel size of 8.74 µm after obturation and after apicoectomy. The percentage of voids at the interface between the filling material and the root canal wall was evaluated in the apical 4 mm of the root after apicoectomy, besides the time cutting to both devices. The data obtained were submitted to paired and unpaired t-tests (α = 0.05). Endo-Z and Bladesonic increased the percentage of voids between the filling material and the dentin after apicectomy (p<0.05), and they were similar (p>0.05). Endo-Z has a shorter time to perform apicoectomy compared to Bladesonic (p<0.05). Apicectomies with Endo-Z or Bladesonic could harm the material/dentin interface, while the Endo-Z bur was faster than the Bladesonic ultrasonic tip.


Resumo O objetivo deste estudo foi avaliar o efeito da apicectomia realizada com broca ou inserto ultrassônico na adaptação do material obturador á dentina do canal radicular. Vinte incisivos inferiores humanos extraídos foram selecionados e preparados com o sistema ProDesign Logic até o diâmetro 40/.05. Os canais radiculares foram obturados com Bio-C Sealer (Angelus, PR, Brasil) por meio da técnica de cone único e foram armazenados em estufa a 37ºC e umidade relativa de 95% por 7 dias. Após esse período, foi realizada apicectomia dos 3 milímetros apicais utilizando broca Endo-Z (Maillefer - Dentsply) ou inserto ultrassônico BladeSonic (Helse Ultrasonic, Santa Rosa de Viterbo, Brasil) (n=10). Os espécimes foram escaneados por meio de microtomografia computadorizada (micro-CT; SkyScan 1176) com tamanho de voxel de 8,74 µm após obturação e após apicectomia. Please, correct this sentece to O percentual de falhas na interface entre o material obturador e a parede dentinaria foi avaliado nos 4 mm apicais da raiz apos apicectomia, alem do tempo de corte para ambos dispositivos. Os dados obtidos foram submetidos aos testes t pareado e não pareado (α = 0,05). Endo-Z e Bladesonic aumentaram o percentual de vazios entre o material obturador e a parede da dentina após apicectomia (p<0.05), sendo semelhantes entre si (p>0.05). Endo-Z demonstrou menor tempo para realizar apicectomia em comparação com Bladesonic (p<0.05). Apicectomias com Endo-Z ou Bladesonic podem prejudicar a interface material obturador/dentina, sendo a broca Endo-Z mais rápida que a ponta ultrassônica Bladesonic.

7.
Braz. dent. j ; 34(5): 36-42, Sept.-Oct. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1528022

ABSTRACT

Abstract Evaluate the shaping ability and preparation time using a pediatric motor-driven rotary instrumentation compared to other systems in resin prototypes of primary molars. Methods: Thirty specimens were scanned in micro-CT and divided into three groups according to the instrumentation type: pediatric motor-driven Sequence baby File (SBF); conventional motor-driven (Sequence Rotary File - SRF); manual K file. Instrumentation time was timed. After preparation, the specimens were scanned again. The pre- and post-instrumentation images were superimposed to measure the amount of root canal deviation and the resin remnant thickness. ANOVA followed by the Tukey test analyzed the comparisons between groups (p<0.05). Results: No statistically significant differences occurred in root canal deviation among groups (p>0.05). There were statistically significant differences in the comparison among root thirds (p<0.001) but without significant differences in the interaction group vs. root third (p>0.05). Both motor-driven instrumentations showed statistically greater weariness than manual instrumentation (p<0.001), without significant significant differences between SBF and SRF. Motor-driven instrumentation had a shorter working time than manual instrumentation (p<0.001). Conclusion: Pediatric motor-driven instrumentation demonstrated good outcomes in relation to root canal deviation and amount of remnant structure, with shorter instrumentation time. SBF can be a suitable alternative for endodontic instrumentation in primary molars.


Resumo Objetivo: Avaliar os resultados da instrumentação endodôntica e o tempo de preparo de lima odontopediátrica ativada por motor (Sequence Baby File- SBF) em canais de molares decíduos prototipados. Métodos: Trinta espécimes foram escaneados em micro-CT e divididos em três grupos de acordo com o tipo de instrumentação: mecanizada odontopediátrica (SBF); mecanizada convencional; lima K manual. O tempo de instrumentação foi cronometrado. Após o preparo, os espécimes foram escaneados novamente. As imagens pré e pós-instrumentação foram sobrepostas e a quantidade de desvio do canal radicular e a espessura de resina remanescente foram mensurados. Para as análises de comparações entre os grupos foram realizados teste ANOVA seguido do teste de Tukey (p<0,05). Resultados: Não ocorreram diferenças estatisticamente significativas entre os grupos no desvio do canal radicular (p>0,05). Houve diferenças estatisticamente significativas na comparação entre terços radiculares (p<0,001), mas sem diferenças significativas na interação grupo vs. terço radicular (p>0,05). A instrumentação mecanizada apresentou desgaste estatisticamente maior do que a instrumentação manual (p<0,001), sem diferenças estatísticas entre a SBF e a lima mecanizada convencional. A instrumentação mecanizada teve menor tempo de trabalho quando comparado a instrumentação manual (p<0,001). Conclusão: A instrumentação mecanizada odontopediátrica demonstrou bons resultados em relação ao desvio do canal radicular e quantidade de estrutura remanescente, com menor tempo de instrumentação. A SBF pode ser uma alternativa adequada para a instrumentação endodôntica em molares decíduos.

8.
Odovtos (En línea) ; 25(2)ago. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1448747

ABSTRACT

The aim of this study was to assess the influence of micro-computed tomography (micro-CT) voxel size on evaluation of root canal preparation using rotary heat-treated nickel-titanium files. Curved mesial root canals of mandibular molars were prepared using ProDesign Logic 30/.05 (PDL) or HyFlex EDM 25/.08 (HEDM) (n=12). The specimens were scanned using micro-CT with 5μm of voxel size before and after root canal preparation. Images with sub-resolution of 10 and 20μm voxel sizes were obtained. The percentage of volume increase, debris and uninstrumented root canal surface were analyzed in the different voxel sizes. Data were compared using unpaired Student's t-test and ANOVA statistical tests (α=0.05). No differences were observed for percentage of volume increase, debris and instrumented surface between the root canals prepared by PDL and HEDM (p>0.05). Both systems promoted higher percentage of debris in the apical third compared to the middle third (p0.05). PDL and HEDM had similar root canal preparation capacity. Micro-CT images using different voxel sizes did not influence the results of volume increase and debris evaluation. However, images at 5µm showed greater accuracy to evaluate the percentage of uninstrumented surfaces.


El objetivo de este estudio fue evaluar la influencia del tamaño de vóxel de la microtomografía computarizada (micro-CT) en la evaluación de la preparación del conducto radicular utilizando limas rotatorias de níquel-titanio tratadas térmicamente. Se prepararon conductos radiculares mesiales curvos de molares mandibulares usando ProDesign Logic 30/.05 (PDL) o HyFlex EDM 25/.08 (HEDM) (n=12). Las muestras se escanearon usando micro-CT con un tamaño de vóxel de 5μm antes y después de la preparación del conducto radicular. Se obtuvieron imágenes con subresolución de vóxeles de 10 y 20μm. Se analizó el porcentaje de aumento de volumen, residuos y superficie del conducto radicular no instrumentado en diferentes tamaños de vóxel. Los datos se compararon usando la prueba t de Student no pareada y las pruebas estadísticas ANOVA (α=0,05). No se observaron diferencias en el porcentaje de aumento de volumen, detritus y superficie instrumentada entre los conductos radiculares preparados por PDL y HEDM (p>0,05). Ambos sistemas promovieron un mayor porcentaje de detritos en el tercio apical en comparación con el tercio medio (p0,05). PDL y HEDM tenían una capacidad de preparación del conducto radicular similar. Las imágenes de micro-CT que utilizan diferentes tamaños de vóxel no influyeron en los resultados de la evaluación del volumen y los desechos. Sin embargo, las imágenes de 5µm mostraron una mayor precisión al evaluar el porcentaje de superficies no instrumentadas.

9.
Braz. dent. j ; 34(1): 29-38, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420580

ABSTRACT

Abstract The aim of this study was to evaluate the physicochemical properties, cytotoxicity and bioactivity of a ready-to-use bioceramic material, Bio-C Repair (Angelus), in comparison with White MTA (Angelus) and Biodentine (Septodont). The physicochemical properties of setting time, radiopacity, pH, solubility, dimensional and volumetric changes were evaluated. Biocompatibility and bioactivity were assessed in Saos-2 osteoblast cell cultures by the MTT assay 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide), Neutral Red (NR), Alizarin Red (ARS), and cell migration tests. Statistical analysis was performed by ANOVA, Tukey or Bonferroni tests (α = 0.05). Bio-C Repair had the longest setting time (p < 0.05), but radiopacity and solubility were accordance with the ISO 6876/2012 standards, besides linear expansion. Bio-C Repair and MTA had similar volumetric change (p > 0.05); lower than Biodentine (p < 0.05). All the materials evaluated had an alkaline pH. Bio-C Repair was cytocompatible and promoted mineralized nodule deposition in 21 days and cell migration in 3 days. In conclusion, Bio-C Repair had adequate radiopacity above 3mm Al, solubility less than 3%, dimensional expansion, and low volumetric change. In addition, Bio-C Repair promoted an alkaline pH and presented bioactivity and biocompatibility similar to MTA and Biodentine, showing potential for use as a repair material.


Resumo O objetivo deste estudo foi avaliar as propriedades físico-químicas, citotoxicidade e bioatividade de um novo material biocerâmico pronto para uso, Bio-C Repair (Angelus), em comparação com MTA Branco (Angelus) e Biodentine (Septodont). Foram avaliadas as propriedades físico-químicas de tempo de presa, radiopacidade, pH, solubilidade, alterações dimensionais e volumétricas. A biocompatibilidade, bioatividade e capacidade de reparo foram avaliadas em culturas de células de osteoblastos Saos-2 pelo ensaio MTT brometo de 3-(4,5-dimetiltiazol-2-il)-2,5-difeniltetrazólio), vermelho neutro (NR), vermelho de alizarina ( ARS) e testes de migração celular. A análise estatística foi realizada pelos testes ANOVA, Tukey ou Bonferroni (α = 0,05). Bio-C Repair apresentou o maior tempo de presa (p < 0,05), mas radiopacidade e solubilidade de acordo com as normas ISO 6876/2012, além de expansão linear. Bio-C Repair e MTA tiveram variação volumétrica semelhante (p > 0,05), menor que Biodentine (p < 0,05). Todos os materiais avaliados apresentaram pH alcalino. Bio-C Repair foi citocompatível, além de promover deposição de nódulos mineralizados em 21 dias e migração celular em 3 dias. Em conclusão, o Bio-C Repair apresentou radiopacidade adequada acima de 3mmAl, solubilidade menor que 3%, expansão dimensional e baixa perda volumétrica.. Além disso, o Bio-C Repair promoveu um pH alcalino e apresentou bioatividade e biocompatibilidade semelhantes ao MTA e Biodentine, mostrando potencial para uso como material reparador

10.
Braz. oral res. (Online) ; 37: e059, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439753

ABSTRACT

Abstract The aim of this study was to compare the quantification of hard-tissue debris by using micro-computed tomography (micro-CT) and nano-focus computed tomography (nano-CT) after root canal instrumentation. Ten mandibular molars containing an isthmus in the mesial root were scanned in a SkyScan 1172 micro-CT device with a voxel size of 12.8 µm and in a NanoTom nano-CT device with 5.5 µm. The mesial root canals were irrigated with 5 mL of saline solution at the orifice level, instrumented with Reciproc R25 files and a second scanning was performed by micro-CT and nano-CT devices for post-instrumentation images. DataViewer software was used for registering the pre- and post-operative micro-CT and nano-CT images. The root canal and the debris were segmented for quantitative analysis of the volume of the canal and volume of debris using CTAn software. Statistical analysis was performed using the T test for comparison between volume of the canal after instrumentation and volume of debris in both image modalities. The level of significance was set at p < 0.05. Nano-CT images showed higher values of debris when compared with micro-CT (p < 0.05) after root canal instrumentation. No difference was observed between the volume of the root canal after instrumentation in the two imaging methods used (p > 0.05). Nano-CT technology can be recommended as a more precise method for quantitative analysis of hard-tissue debris. Moreover, in Endodontic research it is a promising method, as it is capable of providing higher spatial and contrast resolution, faster scanning and higher image quality.

11.
Pesqui. bras. odontopediatria clín. integr ; 23: e210162, 2023. tab, graf
Article in English | LILACS, BBO | ID: biblio-1431047

ABSTRACT

ABSTRACT Objective: To compare the agreement of images in white light (WL), fluorescence (FL), and digital radiographs (DR), on the diagnosis and treatment decisions for occlusal caries lesions against a micro-CT gold standard. Material and Methods: Ten extracted third molars, with enamel and/or dentin caries (ICDAS 2-4), were included. Occlusal surface images were acquired with an intraoral camera (SoproLife®) in WL and FL modes. DR was obtained using an intraoral X-ray and a semi-direct digital system. A total of 780 images were needed, organized in a template, to be later examined by twenty-six dentists invited to compose the study. The Generalized Estimation Equations model was used to compare the proportions of the correct answers between the three methods and the gold standard. When significant, Bonferroni post-hoc test was used to identify differences (α=5%). Results: Most of the examiners were specialists (76.9%) with 14.5 years of experience. All diagnostic methods were similar and showed low agreement (DR 12.7%, WL 16.5%, and FL 16.5%) compared with gold standard caries diagnostic scores. Regarding treatment decisions, mean agreement for all diagnostic methods was higher (43.2%; p<0.001), and among all methods, WL (48.1%) and FL (51.2%) modes performed better than DR (30.4%, p<0.001). Conclusion: SoproLife® images could help clinicians to propose rational, minimally invasive treatments for occlusal caries lesions.


Subject(s)
Humans , Dental Caries/diagnostic imaging , X-Ray Microtomography/methods , Fluorescence , Clinical Decision-Making , Molar, Third/injuries , Effectiveness , In Vitro Techniques/methods , Cross-Sectional Studies/methods , Radiography, Dental, Digital/methods
12.
Braz. j. oral sci ; 22: e231303, Jan.-Dec. 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1442844

ABSTRACT

Aim: To evaluate the potential of inducing mineral density changes of indirect pulp capping materials applied to demineralized dentin. Methods: A total of 50 cavities were prepared, 5 in each tooth, in extracted ten molars without caries, impacted or semi-embedded. The cavities were scanned by microcomputed tomography (µ-CT) after creating artificial caries by microcosm method (pre-treatment). Each cavity was subjected to one of 5 different experimental conditions: control (dental wax), conventional glass ionomer cement (Fuji IX GP Extra), resin-modified calcium silicate (TheraCal LC), resin-modified calcium hydroxide (Ultra-Blend Plus), MTA (MM-MTA) and the samples were kept under intrapulpal pressure using simulated body fluid for 45 days. Then, the second µ-CT scan was performed (post-treatment), and the change in dentin mineral density was calculated. Afterward, elemental mapping was performed on the dentinal surfaces adjacent to the pulp capping agents of 5 randomly selected samples using energy dispersive X-ray spectroscopy (EDS) apparatus attached to a scanning electron microscope (SEM). The Ca/P ratio by weight was calculated. Friedman test and Wilcoxon Signed Ranks test were used to analyze the data. Results: There was a significant increase in mineral density values of demineralized dentin after treatment for all material groups (p<0.05). Resin-modified calcium silicate had similar efficacy to MTA and conventional glass ionomer cement, but was superior to resin-modified calcium hydroxide in increasing the mineral density values of demineralized dentin. Conclusions: Demineralized dentin tissue that is still repairable can be effectively preserved using materials with remineralization capability


Subject(s)
Spectrometry, X-Ray Emission , Calcium Hydroxide , Silicates , Calcium Compounds , X-Ray Microtomography , Glass Ionomer Cements
13.
Braz. oral res. (Online) ; 37: e102, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1520521

ABSTRACT

Abstract The aim of this study was to evaluate root canal preparation with nickel titanium rotary instruments and complementary preparation with ultrasonic tip in curved canals of mandibular molars with isthmus. Twenty-eight mesial roots of mandibular molars with curvature between 20° and 40° and presence of isthmus throughout the entire extension of the root canals were prepared using ProDesign Logic CM (PDL) up to size 40.05, or HyFlex EDM (HFEDM) up to size 40.04. Complementary preparation was performed in the isthmus region using the ultrasonic insert E18D (Helse, Istmo Diamantada). The root canals were scanned using micro-CT (SkyScan 1176) at 9 µm voxel size before and after each preparation step. Transportation, percentage of increase in volume, debris and uninstrumented surface (UNS) were evaluated. Mann Whitney, Wilcoxon, paired and non-paired t-tests were used for statistical analysis (α = 0.05). The canals prepared with PDL and HFEDM obtained similar results for all the variables assessed before using E18D (p > 0.05). E18D significantly decreased the percentage of debris and UNS values in both Groups (p < 0.05). The complementary preparations with E18D caused a smaller quantity of debris in the isthmus of the canals previously prepared with PDL in comparison with HFEDM (p < 0.05). PDL and HFEDM provided similar root canal preparation. PDL promoted a smaller quantity of Debris in the isthmus than HFEDM after using E18D. E18D significantly improved cleaning, and reduced Debris and UNS.

14.
Braz. oral res. (Online) ; 37: e099, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1520522

ABSTRACT

Abstract This study aimed to investigate whether two acquisition parameters, voxel size and filter thickness, used in a micro-computed tomography (micro-CT) scan, together with the examiner's experience, influence the outcome of bone repair analysis in an experimental model. Bone defects were created in rat tibiae and scanned using two voxel sizes of 6- or 12-µm and two aluminum filter thickness of 0.5- or 1-mm. Then, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th) were analyzed twice by two groups of operators: experienced and inexperienced examiners. For BV/TV, no significant differences were found between scanning voxel sizes of 6 and 12 µm for the experienced examiners; however, for the inexperienced examiners, the analysis performed using a 12-µm voxel size resulted in higher BV/TV values (32.4 and 32.9) than those acquired using a 6-µm voxel size (25.4 and 24.8) (p < 0.05). For Tb.Th, no significant differences between the analyses performed by experienced and inexperienced groups were observed when using the 6-µm voxel size. However, inexperienced examiners' analysis revealed higher Tb.Th values when using the 12-µm voxel size compared with 6 µm (0.05 vs. 0.03, p < 0.05). Filter thickness had no influence on the results of any group. In conclusion, voxel size and operator experience affected the measured Tb.Th and BV/TV of a region with new bone formation. Operator experience in micro-CT analysis is more critical for BV/TV than for Tb.Th, whereas voxel size significantly affects Tb.Th evaluation. Operators in the initial phases of research training should be calibrated for bone assessments.

15.
Revista Naval de Odontologia ; 49(1): 19-26, 2022/07/04.
Article in Portuguese, English | LILACS-Express | LILACS | ID: biblio-1379020

ABSTRACT

The objective of this study was to conduct a systematic review focused on studies that used micro-computed tomography (micro-CT) analysis to evaluate untouched canal areas after root canal preparation with continuous rotary and reciprocating kinematics. Electronic search strategies were used in LILACS, PubMed (MedLine), Science Direct, Cochrane, Scopus and Web of Science databases. An additional search for gray literature was performed on Google Scholar, OpenGrey and ProQuest. In addition, manual searches were performed on the reference list of included articles. It covered studies in English, Portuguese and Spanish, without restriction regarding the publication time. The articles selected for inclusion in this review meet all the following criteria: in vitro studies that evaluated, with the use of micro-CT, the percentage of untouched areas after root canal preparation comparing rotary and reciprocating kinematics. A total of 11 studies were selected for qualitative and quantitative analysis. One study showed that the Reciproc system has a smaller percentage of untouched channel walls in lower incisors when compared to BioRace system. Another study showed no significant differences between reciprocating systems Reciproc and WaveOne with BioRace in mesial root canals of lower molars. Similarly, they did not observe any difference between ProTaper Next and ProTaper Universal with WaveOne. A single study showed differences between XP-Endo Shaper system (rotary) compared with WaveOne Gold. The studies evaluated in the present review showed by micro-CT that none of the instrumentation systems, regardless of the kinematics used or NiTi heat treatment, was able to completely touch the root canal walls.


O objetivo deste estudo foi realizar uma revisão sistemática dos estudos que avaliaram por microtomografia computadorizada (micro - CT) as áreas não tocadas do canal radicular após o preparo com cinemática rotatória continua e reciprocante. Foram utilizadas estratégias eletrônicas de busca nas bases LILACS, PubMed (MedLine), Science Direct, Cochrane, Scopus e Web of Science. Uma busca adicional por literatura cinzenta foi realizada no Google Scholar, OpenGrey e ProQuest. A busca abrangeu estudos em inglês, português e espanhol, sem restrição em relação ao tempo de publicação. Adicionalmente, pesquisas manuais foram realizadas na lista de referências dos artigos incluídos. Os artigos selecionados foram estudos in vitro que avaliaram por micro - CT a porcentagem de áreas não tocadas após o preparo do canal radicular, comparando as cinemáticas rotatórias e reciprocante. No total 11 estudos foram selecionados para análise qualitativa e quantitativa. Um estudo mostrou que o sistema Reciproc (reciprocante) tem uma porcentagem menor de paredes não tocadas do canal em incisivos inferiores, quando comparado com o sistema BioRace (rotatório). Outro estudo não mostrou diferenças significativas entre os sistemas reciprocantes Reciproc e WaveOne e o sistema BioRace em canais radiculares mesiais de molares inferiores. Da mesma forma, não foram observadas diferenças entre ProTaper Next, ProTaper Universal (rotat órios) e WaveOne. Um único estudo apresentou diferenças entre as cinemáticas, XP - Endo Shaper (rotatório) mostrou maior porcentagem de áreas tocadas quando comparado com TRUShape e WaveOne Gold. Os estudos avaliados mostraram que nenhum dos sistemas de instrumentação, independente da cinemática, foi capaz de tocar completamente as paredes dos canais radiculares.

16.
Article in English | LILACS-Express | LILACS | ID: biblio-1385888

ABSTRACT

ABSTRACT: This study aims to demonstrate, through a clinical case report, the applicability of the use of microtomography (µCT) in the histopathological evaluation of a ranula lesion on the oral floor and to evaluate the use of 2 % elemental iodine solution as a contrast agent, in order to obtain a better contrast effect in a tissue sample, thus facilitating the identificat ion of anatomical structures, the histomorphological evaluation and the potential use of µCT in the imaging diagnosis of lesions. Different parameters were evaluated for obtaining images in SkyScan 1172, in a biopsied piece, when impregnated in a 10 % formalin solution and in a 2 % elemental iodine solution, when impregnated for 24h and 48h. Contrast agent impregnation was evaluated using the Hounsfield unit. The use of µCT allowed the identification of sialoliths dispersed inside the biopsy specimen, while the impregnation with Elemental iodine 2 % for 24h resulted in a better contrast when compared to the other conditions. The use of the Hounsfield unit allowed an adequate evaluation of the contrast obtained when the different parameters of impregnation and image acquisition were applied. The comparison between the 3D images with and without a specific marker highlighted a better evidencing of the soft tissues, with an improvement in the contrast of the images, also allowing the ident ification of the glandular duct obstructed by the sialoliths, allowing a conclusive histopathological evaluation of the biopsied lesion.


RESUMEN: Este estudio tiene como objetivo demostrar, a través de un reporte de caso clínico, la aplicabilidad del uso de la microtomografía (µCT) en la evaluación histopatológica de una lesión de ránula en el piso de la cavidad oral y evaluar el uso de solución de yodo elemental al 2 % como agente de contraste, con el fin de obtener un mejor efecto de contraste en una muestra de tejido, facilitando así la identificación de estructuras anatómicas, la evaluación histomorfológica y el potencial uso de µCT en el diagnóstico por imágenes de lesiones. Se evaluaron diferentes parámetros para la obtención de imágenes en SkyScan 1172, en una pieza biopsiada, cuando se impregna en una solución de formalina al 10 % y en una solución de yodo elemental al 2 %, durante 24 h y 48 h. La impregnación del agente de contraste se evaluó utilizando la unidad Hounsfield. El uso de µCT permitió la identificación de sialolitos dispersos dentro de la muestra de la biopsia, mientras que la impregnación con Yodo Elemental al 2 % durante 24 h resultó en un mejor contraste en comparación con las otras condiciones. El uso de la unidad Hounsfield permitió una adecuada evaluación del contraste obtenido cuando se aplicaron los diferentes parámetros de impregnación y adquisición de imágenes. La comparación entre las imágenes 3D con y sin marcador específico destacó una mejor evidenciación de los tejidos blandos, con una mejora en el contraste de las imágenes, permitiendo además identificar el conducto glandular obstruido por los sialolitos, permitiendo una evaluación histopatológica concluyente de la lesión sometida a biopsia.

17.
Article | IMSEAR | ID: sea-222352

ABSTRACT

Context (Background): Resin composites are the most widely used material for restoring cervical defects. However, the high failure rate of these restorations is still a concern. Aims: The aim of this in vitro study was to evaluate, using microtomography (?CT), the interfacial gap and voids formation in Class V cavities in premolars restored with materials with lower polymerization shrinkage combined with different restorative techniques. Settings and Design: Cervical defects were created in 30 intact premolar and were randomly distributed to be restored by one of the following techniques (n = 6): Composite resin with two increments (CR), organic modified polymer (ORMOCER) with single (OR1) or two increments (OR2, or low viscosity bulk?fill composite resin with single (BF1) or two increments (BF2). Methods and Material: Each tooth was scanned before filling to determine the volume of interest (VOI) to be applied in the second ?CT after restoration and to control the cavity volume among the groups. In the ?CT after filling, the volume of interfacial gaps and voids was calculated for each group. Statistical Analysis: The groups were compared using one?way and Tukey HSD post hoc test (? = 0.05). Results: It was possible to identify higher gap formation in the OR1 group and higher void formation in CR group (P < 0.05). OR2 group showed better results than the group with one increment. BF2 showed the best filling capacity. Conclusions: It was possible to conclude that the material and the number of increments directly influenced the internal adaptation and voids formation of Class V restorations.

18.
Braz. oral res. (Online) ; 36: e100, 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS, BBO | ID: biblio-1403959

ABSTRACT

Abstract This study aimed to evaluate physicochemical properties of three ready-to-use calcium silicate-based endodontic sealers: Endosequence BC Sealer, Bio C Sealer, and Sealer Plus BC. Radiopacity was evaluated using specimens of 10 mm in diameter and 1 mm in height, along with an aluminum step wedge. For the flow test, 0.5 mL of each sealer was deposited between glass plates and the mean of the measurement of two diameters was considered the cement flow value. For pH and calcium release, root canals of 30 prototypes of upper incisor acrylic resin teeth were filled with sealer and gutta percha point and then immersed in containers with 13 mL of ultrapure water. Both pH and release of calcium ions (atomic absorption spectrophotometer) were measured at 3, 24, 72, and 168 h. Acrylic resin teeth were scanned by Micro-CT 1174 at the time of pH and calcium ion readings for volumetric change analysis. The data were analyzed by ANOVA, Tukey's, Kruskal-Wallis, and Dunn's tests. Endosequence BC Sealer presented the lowest, and Bio C Sealer the highest volumetric change after 72 h and 168 h (p < 0.05). Endosequence BC Sealer presented higher radiopacity (p < 0.05). All materials showed alkalinization capacity. All of them presented calcium ion release, with a higher value for Sealer Plus BC. All materials presented alkalinization, calcium release capacity, radiopacity, and flow above the minimum values required by the ISO standard. The highest volumetric loss was experienced by Bio C Sealer and the lowest one by Endosequence BC Sealer.

19.
Braz. oral res. (Online) ; 36: e115, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1403967

ABSTRACT

Abstract This study evaluate shaping ability of heat-treated NiTi-alloy instruments associated with different final irrigation protocols in flattened root canals. Thirty human mandibular incisors with flattened root canals were divided into 5 groups (n = 10): (XP) Original Protocol XP-endo Shaper; (XP-WT) Original Protocol XP-endo Shaper with working time variation; (XP-K) XP-endo Shaper with kinematics variation; (XP-WTK) XP-endo Shaper with kinematics and working time variations; (Hyflex) Hyflex CM. For the variation in working time protocols the same sample of the XP-endo Shaper groups with and without kinematic variation were used. To evaluate final irrigation protocols, groups 1, 3 and 5 were submitted to 3 protocols: (NI) No irrigation (n = 2); (CI) conventional irrigation (n = 4), and (EndoVac) irrigation (n = 4). The samples were scanned by microcomputed tomography and prepared for scanning electron microscopy evaluation. Quantitative data were evaluated using the parametric ANOVA test, with statistical significance level set at 5%, and qualitative data obtained were compared to establish the agreement between examiners through the Kappa test. It was observed that in the analysis of XP-endo Shaper protocols, the additional working time did not cause difference in any of parameters evaluated (p > 0.05) in relation to time recommended by manufacturer. Compared to Hyflex, XP-K showed highest mean volume increase (p < 0.05) and lowest percentage of untouched walls (p < 0.05). In the qualitative evaluation, final irrigation protocol with EndoVac provided the best cleaning results when associated with XP-K and with Hyflex. Thus, supplementary techniques are effective tools to enhance cleaning and to promote higher touch of walls during root canal preparation.

20.
Pesqui. bras. odontopediatria clín. integr ; 22: e210112, 2022. tab, graf
Article in English | LILACS, BBO | ID: biblio-1386810

ABSTRACT

Abstract Objective: To evaluate the efficacy of silver diamine fluoride (SDF) in arresting dentin caries lesions when applied under different concentrations and times. Material and Methods: Forty-two bovine blocks were selected and fixed in 24-well plates. Each well received a mixed bacterial inoculum added to the culture medium with 5% sucrose. The plates were incubated in microaerophilia (7 days) for caries formation, confirmed by micro-CT (M1). SDF was applied over the carious lesions for different times and concentrations (n=6): SDF 30% - immediate removal, 1 minute and 3 minutes; SDF 38%, - immediate removal, 1 minute and 3 minutes. The group without treatment was the control. Then, the samples were again scanned by micro-CT (M2) and submitted to a second cariogenic challenge for 21 days. Then, a final scan was performed (M3). Results: Mean pH at the culture medium and lesion depth were compared using Kruskal-Wallis and Wilcoxon tests. 38% SDF showed the lowest metabolic activity of the biofilm. All 38% groups and 30% 1 and 3 minutes did not show an increase in mean lesion depth comparing M3 with M1. However, only 30% 3 minutes and 38% 1 and 3 minutes showed a significant reduction of lesion depth. Conclusion: The minimum application time of 30% SDF to arrest dentin caries lesion was 1 minute, while 38% SDF arrested with application and immediate removal.


Subject(s)
Animals , Cattle , Tooth Remineralization , Cariostatic Agents/therapeutic use , Dental Caries/epidemiology , Dentin , Diamines/chemistry , Fluorides/chemistry , Silver/therapeutic use , In Vitro Techniques/methods , Longitudinal Studies , Statistics, Nonparametric , Biofilms , X-Ray Microtomography/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL